On Fisher & Paykel SmartLoad dryers such as the DEGX1 and DGGX1, Code 16 means airflow is restricted. The dryer has found that air is not moving through the drum and vent as it should. The…
On Fisher & Paykel SmartLoad dryers such as the DEGX1 and DGGX1, Code 16 means airflow is restricted. The dryer has found that air is not moving through the drum and vent as it should. The listed places to check are the lint filter, the venting, the thermostat and the motor control module. Owners see Code 16 along with long drying times and a hot cabinet.
1. Unplug the dryer and let it cool. 2. Remove the lint screen and clean it, rinsing away any film. 3. Pull the dryer forward carefully and look for a crushed vent hose. 4. Clear the outside vent flap of lint, then run a short cycle. If Code 16 returns, call us.
The dryer moves hot air through the clothes and out through the vent. Restricted air causes heat to build up, so the dryer reports Code 16 and stops to protect itself.
Start with the lint screen, then the vent hose and the outside flap. Most Code 16 cases begin with lint, and clearing it is safe once the dryer is unplugged and cool.
Then the thermostat or the motor control module may be the cause. We test them, give a written price and cover our repair with a 30-day workmanship warranty.
A technician diagnoses it on site and gives you the price in writing before any work starts.