On Fisher & Paykel ActiveSmart Ice & Water refrigerators such as the E522BLXFDU, Code 41 means solenoid transistor 2 on the controller has shorted. It is the second driver for the ice maker solenoid. The ice…
On Fisher & Paykel ActiveSmart Ice & Water refrigerators such as the E522BLXFDU, Code 41 means solenoid transistor 2 on the controller has shorted. It is the second driver for the ice maker solenoid. The ice maker stops filling correctly, and the LCD shows the code. It is the second of two drivers on the control, so the ice maker may still fill at times while the code shows. A leaking valve can leave ice frozen into a lump, so look for that too.
1. Unplug the refrigerator for five minutes and restart. 2. Shut the water valve if you hear water running at odd times. 3. Check behind the unit for drips. 4. If Code 41 returns, call us. Dry any water you find, and tell us about it when you call.
Code 40 is transistor 1; Code 41 is transistor 2. Both drive the ice maker solenoid. The driver is part of the control module. Ask us about the repair on the visit.
The dispenser has its own valve, so often yes. Turn off water to the ice maker if it leaks. Water for the dispenser is separate, so it often keeps working.
Testing, then replacing the control module if needed. A written quote comes first, and we give a 30-day workmanship warranty. The module is replaced only after you approve the price.
A technician diagnoses it on site and gives you the price in writing before any work starts.